这是描述信息
/
/
LX33 Transformar Based Series UPS
8

LX33 Transformar Based Series UPS

10KVA-200KVA 3/3 phase PF0.8
Transformar based
double conversion
online
Product description
Parameters

Features

Pure sine wave output

Wide input voltage

Friendly interface design ofLCD

Cold start

Isolation transformer

Microprocessor control, self-check, battery check by itself

Online static bypass, strong protection for overload and UPS fault

RS232 & SNMP for optional, to provide remote control management

Intel lgent temperature contolled fan, long life and low noise

Good load compatblity

Parameters

Model LX33 10K LX33 15K LX33 20K LX33 30K LX33 40K LX33 60K LX33 80K LX33 100K LX33 120K LX33 160K LX33 200K
Capacity 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA
Input Voltage 380VAC±20%
Frequency 50Hz±5%/60Hz±5% Auto sensing
Output Voltage 220-244VAC(can be set)
Frequency 50Hz±0.05%/60Hz±0.05%(free running)
Dynamic Response Full Load±5%
Wave Form Sine Wave
Crest Factor 3:1
Efficiency >92% >92% >93%
Rated Output PF 0.8
Distortion THD Non Linear Load THD<5%;Linear Load THD<3%
Overload Load <110% after 5h Transfer to Bypass and Recover Automaticly
Load 110% -125% after 10min Transfer to Bypass and Recover Automaticly
Load 125%-150% after 1min Transfer to Bypass and Recover Automaticly
Battery Type Valve Controlled Sealed Lead-acid Battery
DC Voltage 384VDC 432VDC 480VDC
Quantity for
Standard Backup
12V*32pcs 12V/7Ah*36pcs 12V/7Ah*40pcs
Transfer Time Bypass to Inverter 0ms
Inverter to Bypass <2ms
Protection Short Circuit Shut Off Inverter and Bypass Output at The Same Time
Over Temperature >85℃ Transfer to Bypass Output Automaticly
EMI Filter EN62040-2A Class
Battery Current Breaker
Display LCD Input Voltage、Output voltage、Current、Frequency、Battery Voltage、Load、UPS Status、Temperature etc.
LED Input/Bypass/Inverter/Battery /Overload/Fault
Alarm AC Fault Alarm Every 4 Seconds
Battery Low Voltage Continuely Alarm Every Second Until UPS Shut Down,Battery LED Flash Every 2 Seconds
UPS Overload Continuely Alarm
UPS Fault Continuely Alarm
Communication Interface RS232;Dry Contact
Environment Temperature 0℃-40℃
Humidity <95%(no condensing)
Noise(at 1 meter) <52dB <60dB <62dB
Weight(Net Weight) 210Kg 220Kg 230Kg 282Kg 351Kg 497Kg 556Kg 900Kg 1020Kg 1220Kg 1550Kg
Dimension(W*D*H mm for UPS) 555*825*1200 800*740*1400 1070*745*1400 1420*860*1600

 

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Welcome to Consult Products

Username used for comment:
客户留言
Description:
验证码

Related products

INVERTER WITH CHARGER BATTERY  PAE-2000VA/24V – PAE-3000VA/24V – PAE-4000VA/48V
INVERTER WITH CHARGER BATTERY PAE-2000VA/24V – PAE-3000VA/24V – PAE-4000VA/48V
INVERTER WITH CHARGER BATTERY  PAE-500VA/12V – PAE-1000VA/12V – PAE-1500VA/24V
INVERTER WITH CHARGER BATTERY PAE-500VA/12V – PAE-1000VA/12V – PAE-1500VA/24V
HHR1-20KVA Rack Mount Series UPS
HHR1-20KVA Rack Mount Series UPS
HH1-3KVA High Frequency Series UPS
HH1-3KVA High Frequency Series UPS
这是描述信息

Address

No.2188, Longcheng Road,

Zhonglou District, Changzhou City,

Jiangsu, China

这是描述信息

Our office:

7x24hours online

All rights reserved© ©2020 Changzhou UPSTSTEM POWER CO.,LTD.  2020  Powerd by:www.300.cn   Changzhou   苏ICP备2020053335号-1  Ipv6

keywords:ups power system ups power system ups power system ups power system